R22 pressures - Pacific. DuPont Australia P.O. Box 930 North Sydney, NSW 2060 Australia 61-2-99236111 DuPont Far East Inc. 6th Floor Bangunan Samudra No. 1 JLN. Kontraktor U1/14, SEK U1 Hicom-Glenmarie Industrial Park 40150 Shah Alam, Selangor Malaysia Phone 60-3-517-2534 DuPont Korea Inc. 4/5th Floor, Asia Tower #726, Yeoksam-dong, Kangnam-ku …

 
R22 Pressure: R22 operates at lower pressures compared to 410A. This means systems designed for R22 cannot handle the higher pressure of 410A without modifications. 410A Pressure: 410A operates at a higher pressure, leading to more efficient cooling cycles. However, this requires stronger, more robust components in the …. Peyton manning morgan wallen video

Refrigerant Pressure - Temperature Chart. Pressure values are displayed for R-22, R-410a, R-407c, R-134a and R-404a refrigerants. Items Displayed in Red shows pressure in inches of Mercury. Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information. Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Search Search is the most efficient way to navigate the Engineering ToolBox. Barg pressure is the pressure, in units of bars, above or below atmospheric pressure. The “g” at the end of the word indicates that the measurement is not absolute pressure, someti...Pressure Liquid [psia] 8.8 10.2 11.7 13.4 15.3 17.3 19.6 22.1 24.9 27.9 31.2 34.8 38.7 43.0 47.5 52.5 57.8 63.5 69.7 76.2 83.3 90.8 98.8 107.3 116.3 125.9 136.1 146.9 158.3 170.4 … HVAC R22, 410A Refrigerants! Checking the Charge- Vapor/Suction Operating Pressures, What is Too Low! P/T Chart on the Manifold Gauge Set is Calculated. This... The compound gauge at left is used on the low pressure side of the system and shows pressure readings in black, from 0 to 300 psi gauge pressure. [Click any image to see an enlarged, detailed version.] Temperature corresponding to pressure is shown in red on this gauge for R12 and R22, or for newer refrigerants on newer gauges.R22 5 lb. 10 lbs with cylinder and packaging. FREE SHIPPING NATIONWIDE (CONTINENTAL US) 100% VIRGIN FACTORY SEALED. GUARANTEED PRODUCT …A tech could do a poor job of installing the R22 condenser and the unit would last for 10 years or more. With r410a units, the installers must have there process dialed in tight. No more sweep charging or fast flush. Each system must be vacuumed down to … Table 1 (continued) DuPont™ Freon®22 Saturation Properties — Temperature Table. 7. Table 2 DuPont™ Freon®22 Superheated Vapor — Constant Pressure Tables. V = Volume in m3/kg H = Enthalpy in kJ/kg S = Entropy in kJ/kg•K Saturation Properties in ( ) 8. Table 2 (continued) DuPont™ Freon®22 Superheated Vapor — Constant Pressure Tables. Critical Pressure (psia) 723.7 Critical Temperature (°F) 205.1 Critical Density (lb./ft^ 3) 32.7 Vapor Density (bp,lb./ft^ 3) 0.294 Heat of Vaporization (bp,BTU/lb.) 100.5 Global Warming Potential (CO2 = 1.0) 1810 ASHRAE Standard 34 Safety Rating A1 Refrigerant Boiling Point Physical Properties Refrigerant -80°F -40°F 0°F 40°F 80°F 120°F ... Or download onto your own device. P-T Calculator. This comprehensive Pressure/Temperature calculation tool provides several unique features designed to make the HVAC/R technician’s job easier. Available for iOS and Android devices: For more information, call 800-262-0012. or e-mail [email protected]. TIRE LOAD LIMITS (LBS.) AT VARIOUS COLD INFLATION PRESSURES * NEVER exceed the sidewall markings for the maximum loads and inflation pressures. Note: Letters in parentheses denote Load Range for which Bold Face loads are maximum. International Load Index numbers are shown after the Load Range. Tire Size PSI 70 75 80 85 90 95 100 105 110 115 120 ...Diagnose problems for your R-22 appliance with our complete Pressure Chart. Pressure for all temperatures of this refrigerant.At 318.5 PSI, the saturated temperature is 100°F. If you measure 118 PSI on the low-pressure side of the system, then you know that the saturated temperature of the refrigerant flowing through the …R22 can absorb and release less heat which can lead to compressor burnout over time. On the other hand, R-410A can handle more heat allowing the compressor to run cooler. The compressors used in new AC units are built to withstand greater pressure that is caused by R-410A refrigerant.And other quick methods to relieve your sinus pressure. Blocked sinuses are no fun—especially during a pandemic, when every single seasonal sniffle or sinus headache results in a n... Our Ebook, Paperback, Workbook, Quick Cards: https://www.acservicetech.com/the-book This video is on Normal Operating Pressures are for Freon R-22 and R-410A... R22 refrigerant, (also known as R-22 Freon and HCFC-22 Freon) is a chemical used in both air conditioners and heat pumps to cool your home. On January 1, 2020, the U.S. …R-22 Replacements Pressure-Temperature Guide Key: Green (in of Hg) = Vacuum Black (psig) = Saturated Vapor (calculate Superheat) Bold (psig) = Saturated Liquid (calculate Subcooling)TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors. ADVANTAGE Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881 ...R22 changes from a liquid to a gas in the evaporator coils of the air handler. Normal temperatures: With compressor running and as reference, on a 90 degree F. day: - Goodman runs 45degrees F on low pressure side and 115degrees F on high pressure side.R-22 Refrigerant Pressure-Temperature Chart Author: iGas cited at InspectApedia.com Subject: R22 Refrigerant pressure chart Keywords: R-22, R22, refrigerant,gas,pressure,temperature Created Date: 12/31/2018 2:21:34 PMR22 Pressure enthalpy chart. Scroll down to find download buttons for pressure enthalpy charts in either Metric or Imperial Units. Downloads as a PDF.Compressor suction and discharge pressures for R448A relative to R22 are given below. It may be necessary to reset the pressure cutouts to compensate for the different pressures of the replacement refrigerant. This procedure should be done carefully to avoid exceeding the recommended operating limits of the compressor and other system components.Higher than that. Need suction and liquid line temp to, cant diagnose off just pressures. RIP Ozone. Please call a real pro in you have bo business being on your own if you dont know what superheat and subcooling are.Approved tyre pressures for each engine alternative can be found in the table. All engines, tyres or combinations of these are not always available in all markets. 1 Economical driving. 2 In certain countries the "bar" unit is used alongside the SI unit "Pascal": 1 bar = 100 kPa. Volvo Support for XC90 Approved tyre pressures | Approved … 30 lb. R-22. Cylinder. 50 lb. 125 lb. 1000 lb. 1750 lb. 7th Edition 2020 Refrigerant Reference Guide 17. National Refrigerants, Inc. Product Data Summary and Thermodynamic Tables. R22 has a very similar boiling point to R290 (-41.4°F to 44°F; that’s only a 2.6°F difference). At 100°F, however, the pressure of R22 is 195.9 psig and the pressure of R290 has a pressure of 174.3 psig (check the R290 PT chart below). This is a 20+ psig difference and you will easily tell if you have an R290 or R22 freon. Refrigerant Pressure-Temperature Home Back. Choose Refrigerant: R-410A R-22 °C °F: Psig-40-39-38-37 ... Pacific. DuPont Australia P.O. Box 930 North Sydney, NSW 2060 Australia 61-2-99236111 DuPont Far East Inc. 6th Floor Bangunan Samudra No. 1 JLN. Kontraktor U1/14, SEK U1 Hicom-Glenmarie Industrial Park 40150 Shah Alam, Selangor Malaysia Phone 60-3-517-2534 DuPont Korea Inc. 4/5th Floor, Asia Tower #726, Yeoksam-dong, Kangnam-ku … Table 2 Freon™ 22 Superheated Vapor — Constant Pressure Tables V = Volume in m3/kg H = Enthalpy in kJ/kg S = Entropy in kJ/kg·K Saturation Properties in ( ) R-22a is a hydrocarbon refrigerant blend with primary components including flammable substances such as propane and butane. In some cases, it may also contain small amounts of other hydrocarbons or a pine-scented odorant. This refrigerant is a highly flammable, colorless gas that is heavier than air. “R-22a” has been sold under the names ...Yes. The mass flow rate and operating pressures of Freon™ MO99 are the closest of all the mineral oil compatible replacement products and will likely perform adequately in an existing R-22 system with a capillary tube expansion device. However, for optimal results, it is recommended to replace the capillary tube with a TXV when possible.We would like to show you a description here but the site won’t allow us.Jun 24, 2020. 7 min read. R-22 and R-410A Operating Pressures, Charging, and Recovery Setup! Updated: Nov 20, 2023. In this article, we will discuss an HVAC unit’s refrigerant pressure on both the high side and the low-pressure side while the system runs.R422B is a hydrofluorocarbon refrigerant that comprises of three components. They include two hydrofluorocarbons, R-125, R-134A, and one hydrocarbon, R600A. The refrigerant comes with a variety of features, benefits, and applications. One of the most notable functions is that 422B is a drop-in replacement for R22.What separates it/ or …Normal Refrigerant Operating Pressures Low side 125-135psi Lower ambient temperatures will result in lower low side (suction) pressures. High Side 290-400psi Higher water temperatures will result in higher high side (discharge) pressures. Normal Air Temperature Differential This is the difference in the temperature of the air entering the coil ...As a ballpark & it depends on a lot of factors, suction should be in the range of 60 to 80 & head should be in the range of 150 to 300. I've got a 2.5 ton heatpump, @ 90 degrees in heat mode the suction should be @ 74 and the head should be @ 255. Reply. 05-28-2005, 07:33 PM #6. david2641.Jan 22, 2024 · The perfect refrigerant reading depends on several factors, like atmospheric pressure and temperature. I like to see an average range of 58-85 PSI on the low side and 120-300 PSI on the high side. These indicate that the unit is running okay and should be cooling properly. TL;DR: R22 is almost phased out and even banned. R-22 Refrigerant Fact & Information Sheet. R-22 refrigerant, or Freon, was and still is one of the most popular refrigerants used in the world. R-22 is an HCFC refrigerant and can harm the Ozone layer. It was originally invented by a partnership with General Motors and the DuPont company all the way back in the 1930’s.Jun 24, 2020. 7 min read. R-22 and R-410A Operating Pressures, Charging, and Recovery Setup! Updated: Nov 20, 2023. In this article, we will discuss an HVAC unit’s refrigerant pressure on both the high side …285/45R22 tire pressure chart with maximum tire load capacity at determined tire inflation levels for 285/45R22 tires. TirePressure.org Home Converters Calculators Charts BlogTo make a short story long, R410A and R22 are refrigerants. They are both good refrigerants and they both work, but they have to be charged in the system at different pressures. R410A is a higher pressure system and R22 is a lower pressure system.In this HVAC Training Video, I show you How to Read the Refrigerant P/T Chart for the Pressure-Temperature Relationship. This is used to determine the Temper... Critical Pressure (psia) 723.7 Critical Temperature (°F) 205.1 Critical Density (lb./ft^ 3) 32.7 Vapor Density (bp,lb./ft^ 3) 0.294 Heat of Vaporization (bp,BTU/lb.) 100.5 Global Warming Potential (CO2 = 1.0) 1810 ASHRAE Standard 34 Safety Rating A1 Refrigerant Boiling Point Physical Properties Refrigerant -80°F -40°F 0°F 40°F 80°F 120°F ... What should my normal operating pressures on 410a systems be? R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Educate yourself on whats going on in the heat transfer process.Vapour pressure. An important point when retrofitting is comparing pressures in the system. The figure below shows the vapour pressure curves of several refrigerants according to their dew point.. The lower pressure values of R513A, R1234yf, R134a and R450A make them feasible for applications from -20°C evaporation and up.Mar 29, 2017 ... ... R22. It also has 134a and other variables. Mineral Oil A while back and ... R-22 and R-410A Operating Pressures on Air Conditioners! Checking ...What is the normal operating pressures for a heat pump in heat mode on a 35 degree day? Reply . 12-08-2010, 07:40 PM #2. karsthuntr. View Profile View Forum Posts Visit Homepage View Forum Threads Professional Member* Join Date Mar 2004 Location Grottoes VA Posts 5,849 Post Likes Likes (Given) 0 ...R-22 Low-Side Turn-On Pressure = 50 psig (R22 at 30 deg F) is a typical pressure at which the HVACR compressor/condenser will turn-on 100 psig (R 22 at 85 deg F) is a typical pressure at which the HVACR compressor will turn off [Questionable, further research in process - Ed.]R290 is an excellent alternate to R22. They are pretty comperable in net capacity and efficiency. To see the exact difference, you will need to run selections and balance a system for both refrigerants. R290 is used mostly in refinery or chemical plants as they often have propane in the plant.4. Post Likes. R404 is a better A/C refrigerant because of the lower temps but works like R410 in heating. The discharge temps are lower than the normal for what an R22 system would see. The new dry R22 units have mineral oil in them so they are already compatable with R404.We would like to show you a description here but the site won’t allow us.Although the market prices change constantly, you can expect to pay $4-$6 dollars per pound for R410A. R22 can cost up to $35 per pound, though about $20 per pound, as this shot shows. Note the number of pounds and the cost. 5lbs of R22 is $169 or about $34 per pound. 10lbs of R22 is $219, or almost $22 per pound.R22 Refrigerant Pressure Temperature Chart. Pressure Temp Chart R-11, R-12, R-22, R123, R134A, R404A, R-500, R502. Using an HVAC refrigerant pressure temperature chart is necessary to be sure a unit is operating correctly. Below are three free pressure temperature charts that can be used to troubleshoot an HVAC unit.So, what should my r22 pressures be? Temperature of R-22 Refrigerant versus. Pressure Data. R22 Vapor Pressure at Sea Level R-22 Low Side Pressure2 Ambient Temperature in °F1. 95 degrees Fahrenheit (35 degrees Celsius) 68 psi 181.9 psig. 226.4 psig at 110°F (43.3°C) 150 degrees Fahrenheit (65.6 degrees Celsius) 381.7 …Yes. The mass flow rate and operating pressures of Freon™ MO99 are the closest of all the mineral oil compatible replacement products and will likely perform adequately in an existing R-22 system with a capillary tube expansion device. However, for optimal results, it is recommended to replace the capillary tube with a TXV when possible.As a ballpark & it depends on a lot of factors, suction should be in the range of 60 to 80 & head should be in the range of 150 to 300. I've got a 2.5 ton heatpump, @ 90 degrees in heat mode the suction should be @ 74 and the head should be @ 255. Reply. 05-28-2005, 07:33 PM #6. david2641.R22 5 lb. 10 lbs with cylinder and packaging. FREE SHIPPING NATIONWIDE (CONTINENTAL US) 100% VIRGIN FACTORY SEALED. GUARANTEED PRODUCT …404R pressure temperature chart is quite simple to understand. This is a table that tells you precisely what the pressure of R404A is at a certain temperature. At the low end, the pressure of 404A is 0.9 psig. At the high end, the pressure of 404A is 456.8 psig. We are, of course, talking about 404A liquid pressure.Fluctuating head pressure, R22, Piston. Looks like non condensables. Noncondensibles for sure, possibly moisture. -Recover all refrigerant. -If you can change the oil in the compressor might be worth it. -Replace Filter drier. -Triple evac If you have the time. -Charge by weight, then check superheat and add what’s needed.Freon™ 407C has been a popular R-22 replacement because of its properties, which include: Similar cooling capacity, energy efficiency, and pressures as R-22 in systems. An ability to be topped off after a leak, multiple times, with minimal impact on system performance. Safety; Freon™ 407C has an ASHRAE A1 safety classification.R422D, also known as Freon MO29, is an R22 retrofit refrigerant comprised of R125 (65.1%), R134a (31.5%), and R600a (3.4%). It has a low boiling point of -44.7°C (-48.5°F) at 1 atmospheric pressure. That’s why is used in low-temp applications such as air conditioners and cars. Here is what you can use this R422D pressure temperature chart for:Already Tried: EPA certified, added some refrigerant. High side reads about 250 give or take at 90 degrees ambient temperature. Low side reads 43. Using farthest outside scale on gauge. Answered in 3 minutes by: HVAC Technician: Bart Jay. generally it should be around 225 on the high side and near 70 on the low.Up to 10% lower capacity. Lubricant Recommendation: Compatible with mineral and alkylbenzene oil and if oil return becomes a concern, addition of polyolester lubricant in 5% increments could help resolve the issue. Retrofitting to: R-422B for R-22 Air Conditioning page 95. R-422B for R-22 Refrigeration page 95.Vapour pressure. An important point when retrofitting is comparing pressures in the system. The figure below shows the vapour pressure curves of several refrigerants according to their dew point.. The lower pressure values of R513A, R1234yf, R134a and R450A make them feasible for applications from -20°C evaporation and up. To make a short story long, R410A and R22 are refrigerants. They are both good refrigerants and they both work, but they have to be charged in the system at different pressures. R410A is a higher pressure system and R22 is a lower pressure system. The R410a systems also use synthetic oil for lubrication instead of mineral oil as in R22 systems. The synthetic oil is more soluble and more effective for the whole system. Therefore, R410a performs better than R22 and has improved machine performance. R410a Vs. …Argument #1: Pressure. Tube-side materials in R-410A coils need to be thicker due to the higher operating pressures associated with R-410A relative to R-22. We’re not arguing that there’s not a difference in operating pressure between the two. There is – roughly 130 PSI for R-410A evaporators compared to about 70 for R-22.Mini Split Sizing Basics Video https://youtu.be/9L3l4sXRES8How to work on mini splits? Video https://youtu.be/93ZD8po4ln8How to braze copper? Video https://y... Printable PDF. Temperature (°F): Temperature (°C): R22 Pressure (psig): -60°F. -51.1°C. R22 phase out quick facts. From 2016 to 2029, imports are limited to 2.5 ODPt of HCFC annually (about 45 tonnes of R22). From 1 January 2030, bulk R22 imports will be banned entirely. From 1 January 2020, bulk R22 imported into Australia can only be used for servicing existing refrigeration and air conditioning equipment.Re: R407c Pressures. It is not " taking the micky out of me"! You should be thankful to them, because they are not telling you pressures you expect, but guiding you in right way to do things. They are not giving you fish for one meal, they are guiding you to search for way to learn how to catch fish every time you need a meal..Jake Clark, certified flight instructor, discusses the oil pressure gauge on the R22.A pressure sore is an area of the skin that breaks down when something keeps rubbing or pressing against the skin. A pressure sore is an area of the skin that breaks down when some...Low-Pressure Suction Side. The low-pressure side, when connected to the gauge, should read less than 100 psi. PSI is the common measurement for pressure used in terms of pounds per square inch. By the time the refrigerant reaches these lines it has lost most of its heat and has collapsed into a liquid state, taking up less volume.R-410A systems operate at higher pressures than standard R-22 systems. Do not use R-22 service equipment or components on R-410A equipment. Ensure service equipment is rated for R-410A.! WARNING Refrigeration systems contain refrigerant under pressure. Extreme caution should be observed when handling refrigerants. Wear safety glasses …Typical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming Potential (GWP) refrigerants with a GWP of over 750, will be banned together with the systems using that gas. R410A has a GWP > 2,000.The higher the pressure in the cylinder, the less time it takes to force the refrigerant into the system. The heating element should be turned off before the pressure is above the highest pressure on the Dial-a-Charge® shroud of the refrigerant being used. EXAMPLE: Refrigerant R22 is being used - the pressure at no time should exceed 230 psi.We would like to show you a description here but the site won’t allow us.When servicing and repairing HVAC systems containing R22 refrigerant, having the proper PT reference charts is critical. R22 PT charts provide technicians with essential data on this refrigerant’s pressure and temperature relationship during different phases and conditions. By matching system pressures taken during diagnosis to the expected temperatures on …If, for example, the discharge temperature were 210˚ with a 150 psi head pressure, a 10 psi suction, and a 50˚ outdoor temperature, this would show an extreme undercharge. Subcool and superheat can …Knowing what barometric pressure is can be helpful in many ways. You’ll have a better understanding of the weather and your health when there are changes in barometric pressure. Ch...4. Post Likes. R404 is a better A/C refrigerant because of the lower temps but works like R410 in heating. The discharge temps are lower than the normal for what an R22 system would see. The new dry R22 units have mineral oil in them so they are already compatable with R404.Pressure Temperature Chart 800.497.6805 www.icorinternational.com “making your life easier” COIL TEMPERATURE CHART INSTRUCTIONS Select design temperature for your evaporator and condenser-Match to approx. operational pressures. NU-22 - 120° condensing / 40° evaporator approx. 234 psig head / 60 psig suction

1517 posts · Joined 2009. #2 · Mar 14, 2012. If you are checking the charge then you need to check it by Sub-cooling (TXV) or Super heat (Piston). If you are doing it any other way you are just guessing. The are to many variables to say what should the reading be with an outside temp of 80.. Www drudge

r22 pressures

Comfortmaker heat pump; standard 300/150 hi/lo factory settings; R22 - 5.5lb charge Current pressures: 300/90. I have cleaned condenser and evap coils thoroughly. Both fans working fine. Good air flow through evaporator and condenser. There are no leaks, and no icing.R22 Refrigerant Pressure Temperature Chart. Pressure Temp Chart R-11, R-12, R-22, R123, R134A, R404A, R-500, R502. Using an HVAC refrigerant pressure temperature chart is necessary to be sure a unit is operating correctly. Below are three free pressure temperature charts that can be used to troubleshoot an HVAC unit.What is the normal operating pressures for a heat pump in heat mode on a 35 degree day? Reply . 12-08-2010, 07:40 PM #2. karsthuntr. View Profile View Forum Posts Visit Homepage View Forum Threads Professional Member* Join Date Mar 2004 Location Grottoes VA Posts 5,849 Post Likes Likes (Given) 0 ...R22 changes from a liquid to a gas in the evaporator coils of the air handler. Normal temperatures: With compressor running and as reference, on a 90 degree F. day: - Goodman runs 45degrees F on low pressure side and 115degrees F on high pressure side.For light trucks at 65 to 80 psi, add 5 psi. Then for Class A RVs at 100 to 110, you should add 10 psi from the recommended minimum. There are a lot of details that need to be considered as well as the age …At 318.5 PSI, the saturated temperature is 100°F. If you measure 118 PSI on the low-pressure side of the system, then you know that the saturated temperature of the refrigerant flowing through the middle of the evaporator coil is at 40°F. This is a useful number when combined with the temperature of the tubing near the pressure port. Below we list a dozen causes of high head pressure in an air conditioner or heat pump compressor motor. Of these, debris clogging or malfunctioning TXVs seem to be the most common problems. Air contamination in the refrigerant system. Air flow blocked across the condensing coil. Low condenser airflow will show up as high head pressure, normal ... Our Ebook, Paperback, Workbook, Quick Cards: https://www.acservicetech.com/the-book This video is on Normal Operating Pressures are for Freon R-22 and R-410A...How to calculate normal suction and discharge pressure. Normal discharge and suction pressure chart for different refrigerant. What is the normal suction pressure and discharge pressure of or freon R22 compressor. With 90 F outdoor temperature and 79 F indoor temperature you can expect a 120 F condensing temperature, (ambient plus 30).R410A Systems Run at a Different Pressure. Compared to an R22 system, an R410A air conditioner runs at a higher pressure. These systems operate at about 130 pounds per square inch (psi). In AC mode, an R22 evaporator coil will run at about 70 psi. Therefore, newer systems run at nearly double the pressure, assuming they’re …R22 Pressure: R22 operates at lower pressures compared to 410A. This means systems designed for R22 cannot handle the higher pressure of 410A without modifications. 410A Pressure: 410A operates at a higher pressure, leading to more efficient cooling cycles. However, this requires stronger, more robust components in the …Aug 21, 2018 · August 21, 2018. R-22 was the most popular refrigerant used in commercial and residential air conditioning units for many years because it was considered a safe and cost-efficient refrigerant choice by the HVACR industry. But as anyone in the industry knows, R-22 was phased out in the U.S. beginning in 2010 because it is ozone depleting. The main characteristics of propane, in comparison with R22 and R502, are summarized in table 4. Table 4: cycle comparison R290 Vs R22 R290 Vs R502 HBP LBP Suction Pressure -6% -15% Discharge Pressure -12% -18% Pressure Difference -15% -19% Pressure Ratio -7% -4% Discharge Temperature -16 K -6 KIn this video, I show how a Liquid Line Restriction Affects The Liquid Pressure and Subcooling. I go over the indicators of a Restriction such as vapor satur....